AirTac Fluid Ctrl Valve 2W Series (Int Piloted, Normally Closed)

AirTac Fluid Ctrl Valve 2W Series (Int Piloted, Normally Closed)

Category: Air Valve

Specifications
Details

 

AirTAC 2W Series: Internally Piloted Normally Closed (NC) Valve

The AirTAC 2W Series is a robust 2/2-way internally piloted diaphragm solenoid valve, widely regarded as a standard for industrial fluid control. As a Normally Closed (NC) unit, it blocks flow in its de-energized state and opens when the solenoid coil is powered.

The 2W series is engineered to handle larger flow volumes than direct-acting valves. It uses a pilot-assisted mechanism, meaning it leverages the pressure of the fluid media to lift the diaphragm. This design allows for high flow rates across large pipe sizes while keeping the solenoid coil compact and energy-efficient. It is commonly found in water treatment, automated irrigation, and large-scale pneumatic systems.

Key Product Features

  • High Flow Performance: The diaphragm-style architecture allows for large orifice diameters, making it suitable for high-volume liquid and gas transport.

  • Forged Brass Body: The body is constructed from high-strength brass, providing excellent durability and pressure resistance.

  • Pilot-Operated Efficiency: Because the media pressure helps actuate the valve, it can control high-pressure lines (up to 1.0 MPa) with minimal electrical power.

  • NBR Diaphragm (Standard): Provides a reliable, bubble-tight seal for water, air, and neutral oils.

  • Modular Coil System: Compatible with the full range of AirTAC coils, allowing for easy field replacement or voltage conversion (DC24V, AC220V, etc.).

  • Stable Switching: Designed with an optimized internal bleed path to ensure smooth opening and closing, reducing the risk of internal mechanical wear.


Specifications

 
Model \ Item Port size [Note 1] Orifice size (ømm) Cv Valid area or section (mm²) Weight     [Note 2] (g) Max operating pressure differential Proof pressure
Mpa psi Mpa psi
2W150 - 15 1/2" 15 5.5 100 720 Max : 1.0       Min : 0.05 Max : 150     Min : 10 1.5 220
2W200 - 20 3/4" 20 9.5 170 950
2W250 - 25 1" 25 12.5 220 1200
Specification of coil 
Valve type Coil type Power type Frequency (Hz) Voltage range Electrical entry Power consumption (VA/W) Insulation Temp.      rise (˚C)
2W150                   2W200                  2W250   CDA 116    CLA 116 AC 50 ±15% Terminal  (CDA)   Grommet (CLA) 10.0VA Class B 35
60 8.0VA 30
DC ±10% 6.5W 30
Valve's specification
Acting Internally piloted
Initial state Normally closed
Adaptable fluid Air, Water, Oil
Viscosity limit Under 20 CST
Ambient and fluid temperature (˚C)   Water Air Oil Ambient
Max. 80 90 80 70
Min. 1 -­20 [Note 1] ­-10 [Note 2] -­20 







 

View more about AirTac Fluid Ctrl Valve 2W Series (Int Piloted, Normally Closed) on main site